Corresponding author: Yuri N. Zakharov ( yz-ua3@list.ru ) © 2019 Michael E. Gusev, Yuri N. Zakharov.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Gusev ME, Zakharov YuN (2019) Holographic measurement of surface acoustic wave parameters in crystals. Modern Electronic Materials 5(3): 107-114. https://doi.org/10.3897/j.moem.5.3.51936
|
The theoretical basis of a specialized technique for applying digital holographic interferometry to measure the parameters of surface acoustic waves is presented, a measuring system for visualization and quantitative analysis of the parameters of ultralow-amplitude high-frequency oscillations arising in electronic devices using surface acoustic waves is developed, and experimental results of the study of surface acoustic waves in crystals of lithium niobate are obtained. In this case, to ensure the possibility of recording precision double-exposure interferograms of high-frequency surface acoustic waves, a picosecond pulsed laser with two-stage frequency multiplication was used as a radiation source, and to increase the spatial resolution of the system with the possibility of observing a wide field of view, an adjustable optical zoom of the incoming image was applied to the matrix input (based on charge-coupled devices) of the recording camera and digital zoom was used for obtained interferogram. We achieved the measuring sensitivity of the surface acoustic waves amplitude and spatial-temporal resolution allowing visualization and measurement of surface acoustic waves with amplitudes of the order of 1 nm and frequencies of the order of 10 MHz, which is far beyond the capabilities of standard methods of holographic interferometry.
surface acoustic waves, holographic interferometry, digital holography
Finding the optimum conditions for the formation, propagation and reflection of surface acoustic waves (SAW) provides the possibility of greatly improving the performance of advanced electronic devices employing this physical phenomenon. Typical methods are based on measurements of secondary wave parameters with point detectors at discrete locations and are followed by calculations of wave amplitude, frequency and phase parameters [
It is well-known however that the holographic interferometry method has unique advantages from the viewpoint of visualization and measurement of surface microdeformation [
In this work we analyze results of theoretical and experimental studies aimed at the development of special holographic equipment and method for SAW parameter measurement in solids.
One of the most important factors limiting the applications of holographic interferometry for measurements of nanometer-scale surface motions is the sensitivity of a holographic interferometer an assessment of which will be given below.
The operation principle of a holographic interferometer is as follows. Laser radiation is split into the object beam which illuminates the object and the reference beam directed to the input sensor of the digital video camera. The object beam illuminates the object in the direction ki. The portion of light reflected by the object in the direction kv referred to as the observation direction passes through an optical focusing system and forms an image of the object at the input sensor of the camera. An image domain hologram forms on the CCD matrix of the digital camera as a result of interference between the reference and object beams.
Let R (x, y) be the flat reference wave and U (x, y) the object reflected wave. Then the intensity at the CCD matrix can be described as follows [
I H(x, y) = |RH(x, y)|2 + |UH(x, y)|2 +
R H(x, y)U*H(x, y) + R*H(x, y)UH(x, y), (1)
where H is the hologram plane index and * is the complex conjugation index. The intensity described by Eq. (1) is detected by a 2D electronic device incorporating multiple arrays of sensitive cells (M × N pixels) having the size ∆x × ∆y, thus allowing one to describe the intensity in the form of the function IH(m×x, n×y) where m и n are integers. The last two terms of Eq. (1) contain information on the amplitude and phase of the object wave. This information can be separated by means of spatial filtering using Fourier transform [
(2)
where Re and Im are the real and imaginary parts of the complex number, respectively. Deduction of the phases of the object fields calculated for two states of the object get the phase difference from which once can calculated the shift of the points of the object u in the direction s resulting from the application of a load:
(3)
where λ is the laser wavelength, s is the interferometer sensitivity vector described as s = ki – kv and ki and kv are the unit vectors of the illumination and observation directions, respectively.
It follows from Eq. (3) that the maximum system sensitivity to motions in the surface normal direction (which are the case for SAW) is achieved if the illumination and observation directions are normal to the surface (|s| = 2). Each fringe in the interference pattern has the value λ/2, where λ is the laser wavelength, and this value determines the sensitivity of the interferometer (in the optical region this is 350–200 nm per fringe). If the surface motion range is within λ/2 no fringes form in the interference pattern but the phase distribution in the object waves of two holograms and their phase difference can be calculated from the information derived from discrete pixels of the CCD matrix. The limit sensitivity in this case is determined by the minimum surface shift in the direction of the interferometer sensitivity vector which causes a response of the measuring system.
As follows from Eq. (3) the sensitivity of the holography method is inversely proportional to the laser wavelength used for hologram writing which is well-known for high accuracy (to within the spectral width which is of the order of tens of femtoseconds for holographic lasers). However knowing this fact alone does not allow judging about the minimum dimension of the detected motions.
The basic factor determining the limit sensitivity of a specific design of a holographic measuring system is the resolution of the measuring system which contains multiple components, including the recording CCD matrix, the circuitry and the software. If holograms are recorded and processed with 8-bit digital devices and software the measuring system will finally provide for a 256-grade division of the maximum surface shift magnitude Wmax calculated from the interference pattern, so the value of each grade is as follows:
(4)
Then the measurement data (motion field) are represented as a discrete function of two variables W = F (m∆x, n∆y), where ∆x and ∆y are the pixel dimensions in the image and m and n describe the sequence number of a pixel in each of the axes. The value of the function W is constant within each pixel and is a multiple of ∆W. It follows from Eq. (4) that with a decrease in the overall magnitude of object shift the value of the grade ∆W decreases and becomes the smallest if the interference pattern contains one fringe. As shown above if the optical setup of the interferometer has normal illumination and observation directions the value of one interference fringe is λ/2. Thence the value of one grade or the minimum surface shift magnitude that can be detected by the system (a change to the next grade) can be calculated for this case as follows:
(5)
Due to the specific features of the data digitalization systems used in most experimental instruments the value of one grade calculated with Eq. (5) remains the same regardless of further decrease in the overall shift in the interference pattern (to within portions of a fringe). Thus motions that are smaller in magnitude than the values calculated above will not cause any response of the measuring system. Therefore these values can be accepted as the limit resolution of the measuring system for a specific laser wavelength. It follows from Eq. (5) that the theoretical limit sensitivity of the method for hologram recording with ultraviolet radiation is less than 1 nm. However Eq. (1) does not allow for speckle noise generated by coherent light reflection from surfaces of diffuse reflecting objects. In practice the abovementioned limit sensitivity is only achievable for measurement of motions of objects with mirror surfaces that do not produce high-frequency speckle-structure in the reflected object wave.
Another most important factor limiting the use of holographic interferometry for studies of dynamic processes is the frequency of test object surface oscillations. There are publictions on the application of holographic interferometry for measurement of oscillations at up to 100 kHz frequencies [
Double-exposure interferometry of an oscillating object incorporates recording and interferometric comparison between two holograms one of which is taken for the specimen in rest and the other is recorded after oscillations were generated in the specimen. A most important factor determining the fringe contrast and the measurability of the oscillations is the on-off time ratio k described as follows:
(6)
where T is the object surface oscillation period and t is the exposure time (hologram recording time).
It is well-known that in order for a double-exposure interference pattern of an oscillating surface to become recordable at an oscillation amplitude that is equal to or smaller than the laser wavelength, the on-off time ratio should be at least 10. For standing waves exposure should be synchronized with the onset of surface oscillation phase [
The exposure time of CCD matrices in conventional holographic interferometers with cw laser irradiation [
At k << 1 the object wave intensity is averaged over oscillating object exposure time [
Thus theoretical analysis results in a conventional holographic interferometer does not allow visualization and parameter measurement of oscillations at MHz frequencies due to its long exposure time. To provide for the required on-off time ratio at oscillation frequencies of up to 1 GHz (oscillation period 1 ns) the exposure time should be within 100 ps.
Accepting that SAW-caused motions (deformations) of object surface generate small phase fluctuations of the reflected light wave in one direction one can assume that the interference pattern of specimen surface oscillations will be in the form of a system of parallel low-contrast fringes perpendicular to the SAW propagation direction. If the hologram is recorded with an 1× magnification optical system the phase gradient period in the interference pattern (fringe step) will be equal to the SAW wavelength.
Since holograms are written with CCD matrices the unit resolution will be determined by the CCD matrix pixel size which is at least 5 µm for conventional high resolution cameras.
Basically, to allow recording an interference pattern onto a CCD matrix the division step (pixel size) should be at least 2 times smaller than the fringe step in the interference pattern [
One can easily calculate that for a 4000 mps sound velocity in a lithium niobate crystal this criterion is met for SAW frequencies of up to 400 MHz at which there are 2 pixels per wavelength. At higher frequencies the Nyquist criterion is not met. Furthermore the too small number of pixels per wavelength for SAW frequencies of 10–400 MHz is obviously insufficient for plotting a smooth envelope curve of oscillation motions which is a decisive factor in measurements of wave parameters (wavelength and amplitude). Therefore measuring the parameters of high-frequency SAW requires image magnification at CCD matrix input.
It is also noteworthy that measuring oscillation motion fields for SAW is in fact a self-contradictory task. For example, whereas visualization of a SAW across the entire specimen surface requires the largest observation zone available be provided (minimum image magnification), achieving the highest accuracy of SAW parameter measurements requires maximum magnification thus narrowing the object surface area taken within one exposure time.
To overcome this contradiction and provide for the maximum adaptability of the measuring system one can use a combined two-step image magnification system.
The test specimen was a 50 × 50 × 3 mm3 one-side polished lithium niobate wafer. SAW were excited in the specimen and the response was measured with the interdigital transducers (IDT) D1–D8 applied onto the specimen surface by lithography. The specimen is schematically shown in Fig.
The radiation source of the experimental setup (Fig.
(a) Schematic diagram of experimental setup and (b) general appearance of digital holographic interferometer.
The measurement sequence was as follows.
The parameters of the optical system were selected experimentally with the criterion of optimum hologram recording conditions. SAW were excited by sending an electric signal from the high-frequency generator to the IDT D1. Resonance was tuned by the maximum signal magnitude read by the oscilloscope connected to the IDT D2. The resonance frequency measured was f0 = 17 MHz. Two conventional measuring devices were used (a Tektronix TDS 303 2B oscilloscope and G3-19A and G-102A generators).
In rest (without load) holograms were recorded using a 50 ps pulse laser at λ3 = 0.354 µm. The subsequent series of holograms in excited state at the resonance frequency were recorded with 5–30 s intervals between exposures. Loaded specimen holograms for each measurement area (Fig.
To record interference patterns in all the measurement areas shown in Fig.
The interference patterns were recorded with special hologram processing software providing interference comparison of two holograms and subsequent motion field calculation. The holograms being compared were one for an in-rest object and the other for an excited object.
Figure
To check the possibility of enlarging the observation area per one recording cycle and hence decreasing the number of recording cycles required for visualization of the entire specimen surface we experimented with recording 1.5 : 1 scale holograms in the specimen center. The area recorded per time was 6 × 6 mm2. The resultant interference patterns showed that the spatial resolution of the CCD matrix provides for clear visualization of SAW with this magnification at the test oscillation frequency. To check hologram recording quality we also quantified the interference patterns and as a result found that the entire surface was tilted due to specimen thermal expansion (Fig.
Visualization of SAW in specimen center under thermal deformations: (a) interference pattern, (b) restored motion field and (c) vertical section of motion field in wave vector plane (a and b: 1.5× magnification (1000 × 1000 pixels along horizontal axes correspond to 6 × 6 mm2); b and c: surface shift in vertical plane, µm).
SAW parameters measured in specimen center for excitation by IDT D1 at 17 MHz and in SC mode: (a) interference pattern, (b) digital magnification of selected area in the interference pattern (a); (c) restored motion field and (d) vertical section of motion field in wave vector direction. Magnification 1.5× (pixel size 6 µm). SAW length: 38 pixels × 6 µm = 240 µm, SAW amplitude: 3–3.5 nm.
To determine whether the SAW were standing or traveling we compared the motion functions of one specimen surface area calculated from interference patterns recorded at different arbitrary moments of time. For standing waves the locations of the oscillation loops (peaks of motion function) on the specimen surface should not change in time. Comparison for excitation in SC mode results the waves were standing (Fig.
SAW type check in SC mode by comparing surface motion functions for a specimen area at different arbitrary moments of time: (a and d) interference patterns, (b and e) restored motion field and (c and f) vertical section of restored motion field. Recording instant for the top figures differs from that for the bottom figures by an arbitrary value.
Visualization and parameter measurement of high-frequency acoustic waves in a lithium niobate crystal by means of digital holographic interferometry showed that subject to special measures this method provides the following results:
These limiting parameters of digital holographic interferometry are far better than the applicability limits of conventional holographic interferometry.
The reported experimental limit sensitivity and resolution of the digital holographic interferometry method can be significantly improved through special measures. For example, to improve the sensitivity limit one can use UV lasers for recording digital holograms alongside with cameras and software providing a greater number of grades in image digitizing. To improve the time resolution of the method one can use femtosecond laser pulses. The spatial resolution of the method can be further improved by recording holograms onto CCD matrices with a greater number and smaller sizes of pixels (for example FL3-U3-120S3C-C (FLIR Systems, Inc.) [
Our results confirm that digital holographic interferometry is a promising tool for coherent optical measurements of high-frequency SAW parameters. These results lay the foundation for developing an industrial technology and a variety of measuring devices offering unique measurement capabilities in the solution of a broad range of problems related to SAW electronic components.